Product Comparison

產品特點

Suitable for 2 and 3 Indoor Units (Please download the combination table for further details)

Note:When ASHG18LFCA is connected, connect at least 1 wall mounted type of 8,500BTU (ASHG09LMCA)

Energy Saving

Inverter Cooling / Heating air conditioner

Flexible installation

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 200 - 250 sq.ft.

Total cooling capacity : minimun is 14,000 Btu/h, maximun is 36,000 Btu/h

Safety Tips for Air Conditioner

Automatic Air Flow Adjustment

Auto Restart

Auto Changeover

Connectable Distributing Duct

Connectable Fresh Air Duct

Weekly Timer

Refrigerant R410A, Protect Earth Allopatric 

Suggested area : 300 sq.ft. or above

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Quiet Operation

Inverter Cooling / Heating air conditioner

Moisture Removal

Up/Down Swing Flaps

Automatic Flaps

Auto Shut Flaps

Automatic Air Flow Adjustment

Auto Restart

Sleep Timer

Program Timer

3 selective wind speed (Low, Medium and High)

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 80 - 110 sq.ft.

Safety Tips for Air Conditioner

Quiet Operation

Strong Power 

Program Timer 

Automatic Air Flow Adjustment 

Auto Restart Function 

Weekly Timer 

Connectable Distributing Duct 

Suggested area : 300 sq.ft. or above  

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Grade 1 Energy Label

All DC Inverter cooling / heating

Reverse Cycle Heating System

Economy mode

Powerful mode 

Quiet Operation

Moisture Removal 

6 Steps Up/Down and 5 Steps Left/Right Directional Swing

Automatic Flaps 

Auto Shut Flaps 

Automatic Air Flow Adjustment 

Auto Restart 

Sleep Timer 

Auto-Changeover 

Refrigerant R410A, Protect Earth Allopatric

Supported with smartphone as remote controller (Installation of wireless lan interface UTY-TFNXZ2 is required)

Suggested area : 160 - 200 sq.ft.  

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

 

Suitable for 2 to 4 Indoor Units (Please download the combination table for further details)

Note:Connection of ASHG18L+ARHG09L+ARHG09L+ARHG09L are not available

Note:Connection of ASHG18L+ARHG12L+ARHG09L+ARHG09L are not available

Energy Saving

Inverter Cooling / Heating air conditioner

Flexible installation

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 250 - 300 sq.ft.

Total cooling capacity : minimun is 27,000 Btu/h, maximun is 49,000 Btu/h

Safety Tips for Air Conditioner

Circular Flow

Economy Mode

Moisture Removal

Room Temperature set point limitation

Set Temperature auto return

Connectable distributing duct

Up/down swing flags

Automatic fan speed

Auto restart

Auto-change-over

Weekly timer

Filter sign 

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 210 - 250 sq.ft.

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Outdoor unit height is only 368mm, suitable for window AC hoods

Easy to install without scaffolding work (may be vary depending on different conditions)

Grade 1 Energy label

All DC inverter cooling

Economy Mode

Powerful Mode 

Quiet Operation at a noise level as low as 21dB(A)

Outdoor Unit Low Noise

Moisture Removal

7 Steps Up/Down Directional Swing

Automatic Flaps

Auto Shut Flap

Automatic Air Flow Adjustment

Washable open panel, easily wash

On/Off Timer

Sleep Timer

Auto Restart

Refrigerant R410A, Protect Earth Allopatric

Supported with Wireless LAN control (installation of wireless ian interface UTY-TFNXZ2 and "FGLair" app are required)

Suggested area : 120 - 150 sq.ft.

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Style
Duct Type
Duct
Inverter Wall Mounted Type
Cassette Type
INVERTER WINDOW SPLIT TYPE
Cooling Capacity - Btu/h
35,000
86,700
17,700
22,800
10,900
Cooling Capacity - kW
10.30
25.40
5.20
6.68
3.20
Heating Capacity - Btu/h
21,500
Heating Capacity - kW
6.30
EER (Cooling) - kW
3.42
2.42
3.25
3.70
3.14
COP (Heating) - kW
3.46
Power Consumption (Cooling) - kW
3.01
10.50
1.60
1.81-1.91
1.02
Power Consumption (Heating) - kW
1.82
8.4-8.5
Voltage / Phase / Frequency - V / Ø / Hz
220-240/1/50
400/3/50
220-240/1/50
220/1/50
Dimension (I.U.) HxWxD - mm
300 x 1,400 x 700
450 x 1,550 x 700
320 x 998 x 238
246 x 840 x 840
268 x 840 x 203
Dimension (O.U.) HxWxD - mm
1290 x 900 x 330
1,380 x 1,300 x 650
620 x 790 x 290
830 x 900 x 330
368 x 500 x 490
Dimension (Panel) HxWxD - mm
53 x 950 x 950
Net Weight (I.U. / O.U.) - kg
45/100
85/243
14/41
24/53
8.5 / 27
Remote Control
Wired
Wired
Wireless
Wired
Wireless
Power Supply
Outdoor
Outdoor
Outdoor
Outdoor
Indoor
Origin (Indoor)
Thailand
Thailand
China
Thailand
China
Origin (Outdoor)
Thailand
Thailand
China
Thailand
Thailand
Refrigerant
R410A
R407C
R410A
R410A
R410A
Style
3 Rooms , Inverter Cooling / Heating
Cassette - 1HP , Inverter Cooling / Heating
4 Rooms , Inverter Cooling / Heating
Cooling Capacity - Btu/h
23,200
8,500
27,300
Cooling Capacity - kW
6.8
2.50
8.00
Heating Capacity - Btu/h
27,300
11,300
32,800
Heating Capacity - kW
8.0
3.30
9.60
Power Supply / Phase / Frequency - V/Ø/Hz
230 / 1 / 50
230 / 1 / 50
230 / 1 / 50
Dimension (I.U.) HxWxD - mm
245 x 570 x 570
Dimension (O.U.) HxWxD - mm
700 x 900 x 330
830 x 900 x330
Dimension (Panel) HxWxD - mm
49 x 700 x 700
Net Weight - kg
55
15
68
Origin (Indoor)
China
Origin (Outdoor)
Thailand