Product Comparison

產品特點

All DC Inverter Cooling/Heating

Up/Down Swing Flaps 

Automatic Air Flow Adjustment 

Auto Restart 

Auto Changeover 

Sleep Timer 

Program Timer 
Reverse Cycle Heating System  

Refrigerant R410A, Protect Earth Allopatric  

Suggested area : 160 - 200 sq.ft.

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

 

Quiet Operation

Inverter Cooling / Heating air conditioner

Moisture Removal

Up/Down Swing Flaps

Automatic Flaps

Auto Shut Flaps

Automatic Air Flow Adjustment

Auto Restart

Sleep Timer

Program Timer

3 selective wind speed (Low, Medium and High)

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 160 - 200 sq.ft.

Safety Tips for Air Conditioner

Grade 1 Energy Label 

All DC Inverter cooling / heating

Economy Mode

Powerful Mode

Quiet Operation

Moisture Removal 

7 Steps Up/Down Directional Swing 

Automatic Flaps 

Auto Shut Flaps 

Automatic Air Flow Adjustment 

Auto Restart 

Sleep Timer 

Auto-Changeover 

Refrigerant R410A, Protect Earth Allopatric

Supported with Wireless LAN control (Installation of wireless lan interface UTY-TFNXZ2 and "FGLair" app are required)

Suggested area : 90 - 110 sq.ft.  

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Quiet Operation

Inverter Cooling / Heating air conditioner

Moisture Removal

Up/Down Swing Flaps

Automatic Flaps

Auto Shut Flaps

Automatic Air Flow Adjustment

Auto Restart

Sleep Timer

Program Timer

4 selective wind speed (Quiet, Low, Medium and High)

Refrigerant R410A, Protect Earth Allopatric

Supported with smartphone as remote controller (Installation of wireless lan interface UTY-TFNXZ2 is required)

Suggested area : 210-250 sq.ft.

Safety Tips for Air Conditioner

Automatic Air Flow Adjustment

Auto Restart

Auto Changeover

Connectable Distributing Duct

Connectable Fresh Air Duct

Weekly Timer

Refrigerant R410A, Protect Earth Allopatric 

Suggested area : 300 sq.ft. or above

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Circular Flow

Economy Mode

Moisture Removal

Room Temperature set point limitation

Set Temperature auto return

Connectable distributing duct

Up/down swing flags

Automatic fan speed

Auto restart

Auto-change-over

Weekly timer

Filter sign 

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 260 - 300 sq.ft.

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Grade 5 Energy label 

Refrigerant R410A, Protect Earth Allopatric 

Quiet Operation

Strong Power, the efficiency-improved compressor or heat exchanger quickly changes your room into a comfortable environment 

Wide Angle Airflow

Instant Air Exchange

Suggested area : 160 - 200 sq.ft.

Safety Tips for Air Conditioner

All DC Inverter cooling / heating

Automatic Air Flow Adjustment 

Auto restart 

Auto Changeover 

Sleep timer

Program timer  

Refrigerant R410A, Protect Earth Allopatric  

Suggested area : 160 - 200 sq.ft.

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.) 

Safety Tips for Air Conditioner

 

Cooling Capacity - Btu/h
16,400
Cooling Capacity - kW
4.80
EER Cooling - kW
2.59
Power Consumption - kW
1.85
Power Supply / Phase / Frequency - V / Ø / Hz
220 / 1 / 50
Dimensions (H x W x D) - mm
400 x 660 x 633
Net Weight - kg
59
Refrigerant
R410A
Origin
Thailand
Style
Inverter Cassette (Campact) Type
Inverter Wall Mounted Type
Duct Type
Cassette Type
Inverter Duct Type
Cooling Capacity - Btu/h
17,700
8,900
46,000
28,900
17,700
Cooling Capacity - kW
5.20
2.60
13.50
8.47
5.20
Heating Capacity - Btu/h
20,500
9,900
20,500
Heating Capacity - kW
6.00
2.90
6.00
EER (Cooling) - kW
3.21
3.66
3.37
3.71
3.21
COP (Heating) - kW
3.61
4.20
3.38
Power Consumption (Cooling) - kW
1.66
0.71
4.00
2.33
1.62
Power Consumption (Heating) - kW
2.00
0.69
1.77
Voltage / Phase / Frequency - V / Ø / Hz
230/1/50
380-415/3/50
230/1/50
230/1/50
Dimension (I.U.) HxWxD - mm
245 x 570 x 570
268 x 840 x 203
300 x 1,400 x 700
288 x 840 x 840
198 x 900 x 450
Dimension (O.U.) HxWxD - mm
632 x 799 x 290
535 x 663 x 293
1290 x 900 x 330
914 x 970 x 370
632 x 799 x 290
Dimension (Panel) HxWxD - mm
49 x 700 x 700
53 x 950 x 950
Net Weight (I.U. / O.U.) - kg
15/36
8.5/24
44/102
26.5/77
18.5/36
Remote Control
Wireless
Wireless
Wired
Wired
Wired
Power Supply
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Origin (Indoor)
China
China
Thailand
Thailand
China
Origin (Outdoor)
China
China
Thailand
Thailand
China
Refrigerant
R410A
R410A
R410A
R410A
R410A
Style
Cassette - 2HP , Inverter Cooling / Heating
Wall Mounted - 2.5HP , Inverter Cooling / Heating
Cooling Capacity - Btu/h
17,100
23,200
Cooling Capacity - kW
5.00
6.80
Heating Capacity - Btu/h
20,500
28,200
Heating Capacity - kW
6.00
8.20
Power Supply / Phase / Frequency - V/Ø/Hz
230 / 1 / 50
230 / 1 / 50
Dimension (I.U.) HxWxD - mm
245 x 570 x 570
320 x 998 x 238
Dimension (Panel) HxWxD - mm
49 x 700 x 700
Net Weight - kg
15
14
Origin (Indoor)
China