Product Comparison

產品特點

All DC Inverter cooling / heating

Automatic Air Flow Adjustment 

Auto restart 

Auto Changeover 

Sleep timer

Program timer 

Refrigerant R410A, Protect Earth Allopatric  

Suggested area : 300 sq.ft. or above 

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Grade 1 Energy Label

All DC Inverter Cooling

R32 High Efficiency Refrigerant, reduces Global Warming Potential

Powerful Mode

Economy Mode

6 Steps Up/Down Directional Swing

Automatic Air Flow Adjustment

Auto Shut Flaps

Auto Restart

Moisture Removal

Sleep Timer

12hr Program Timer

Filter Sign

Washable Panel

PM2.5 Filter

Suggested area : 120 - 150 sq.ft.  

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

All DC Inverter cooling / heating

Up/Down Swing Flaps 

Automatic Air Flow Adjustment 

Auto restart 

Auto Changeover 

Weekly + Setback timer 

Reverse Cycle Heating System  

Refrigerant R410A, Protect Earth Allopatric  

Suggested area : 300 sq.ft. or above

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

 

Grade 1 Energy Label
All DC nverter Cooling / Heating
R32 High Efficiency Refrigerant, reduces Global Warming Potential
Powerful Mode
Economy Mode
6 Steps Up/Down and 5 Steps Left/Right Directional Swing
Automatic Air Flow Adjustment
Auto Shut Flaps
Auto Restart
Moisture Removal
Sleep Timer
24hr Program Timer
Filter Sign
Washable Panel
PM2.5 Filter
Suggested area : 160 - 200 sq.ft.  
Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)
Safety Tips for Air Conditioner

Style
Inverter Duct Type
Inverter Wall Mounted Type
Inverter Cassette Type
Inverter Wall Mounted Type
Cooling Capacity - Btu/h
34,100
11,500
34,100
18,000
Cooling Capacity - kW
10.00
3.38
10.00
5.28
Heating Capacity - Btu/h
38,200
38,200
18,000
Heating Capacity - kW
11.20
11.20
5.28
EER (Cooling) - kW
3.52
3.07
4.10
3.52
COP (Heating) - kW
3.90
4.38
4.13
Power Consumption (Cooling) - kW
2.84
1.10
2.44
1.50
Power Consumption (Heating) - kW
2.87
2.56
1.28
Voltage / Phase / Frequency - V / Ø / Hz
400/3/50
220/1/50
400/3/50
220/1/50
Dimension (I.U.) HxWxD - mm
270 x 1,135 x 700
270 x 834 x 222
288 x 840 x 840
280 x 980 x 240
Dimension (O.U.) HxWxD - mm
1290 x 900 x 330
541 x 663 x 290
1,290 x 900 x 330
632 x 799 x 290
Dimension (Panel) HxWxD - mm
50 x 950 x 950
Net Weight (I.U. / O.U.) - kg
40/104
9.5/22
26/104
12.5/35
Remote Control
Wired
Wireless
Wirelss
Wireless
Power Supply
Outdoor
Outdoor
Outdoor
Outdoor
Origin (Indoor)
China
Thailand
China
Thailand
Origin (Outdoor)
Thailand
Thailand
Thailand
Thailand
Refrigerant
R410A
R32
R410A
R32